Sign in →

Test Code PROS Protein S Activity, Plasma

Methodology

Amidolysis of Chromogenic Substrate

Performing Laboratory

Huntsville Hospital Laboratory

Specimen Requirements

1. Draw blood in a blue-top (citrate) tube(s). Spin down, remove plasma, spin plasma again, and place 1 mL of citrate platelet-poor plasma in plastic vial. (Glass vial is not acceptable.)

Note:  Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Freeze specimen immediately at ≤-40° C, if possible.
3. Send specimen frozen.
Note:  1. Each coagulation assay requested should have its own vial.
2. If the patient is being treated with Coumadin®, this should be noted.

3. Lipemic specimen may be rejected.

Reference Values

Female:  55-123 % activity 

Male: 77-143 % activity

Day(s) Test Set Up

Tuesday, Friday

CPT Coding

85306

Secondary ID

HHA1481

LOINC Coding

Test Name LOINC Code

Protein S Activity, Plasma

8265-1

 

Specimen Stability Information

 

Specimen Type

Temperature

Time

Platelet-poor plasma, citrated

RT, spun

4 hrs

  Frozen 2 weeks