Sign in →

Test Code AT3 Antithrombin III Activity, Plasma

Methodology

Chromogenic Substrate

Performing Laboratory

Huntsville Hospital Laboratory

Specimen Requirements

1. Draw blood in a blue-top (citrate) tube(s). Spin down, remove plasma, spin plasma again, and place 0.5 mL of citrate platelet-poor plasma in plastic vial. (Glass vial is not acceptable.)

Note:  Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Freeze specimen immediately at ≤-40° C, if possible.
3. Send specimen frozen.
Note:  1. Each coagulation assay requested should have its own vial.
2. Heparin treatment may lower plasma antithrombin.

Reference Values

80-120%

Day(s) Test Set Up

Tuesday, Friday

CPT Coding

85300

Secondary ID

HHA1209

LOINC Coding

Test Name LOINC Code

Antithrombin III Activity, Plasma

27811-9

 

Specimen Stability Information

 

Specimen Type

Temperature

Time

Platelet poor plasma, citrated Frozen

14 days

 

Reject Due To

 

Hemolysis

Mild:

ok

Gross:

Reject

Lipemia

Mild:

ok

Gross:

ok

Icterus

Mild:

ok

Gross:

ok